Key features


  • Easy to use
  • Results in 20-45 seconds
  • Up to 120 results an hour
  • Imprecision < 1.5% CV

Inquire now >>

Lab accurate glucose and lactate measurement in one test


The Biosen series of glucose analyzers include three different models and are a familiar brand name in laboratories and diabetes clinics.

Biosen analyzers can be manufactured as single channel glucose systems or as dual channel systems that can measure lactate at the same time.

Biosen uses a special chip sensor technology to deliver fast measurements with a high degree of accuracy at a low cost per test. Due to the long life of the sensor chip the system requires little maintenance, features such as the touch screen and large memory only add to the Biosen analyzer’s user-friendliness.

All Biosen analyzers are supplied with an interface to connect to hospital or lab information systems (LIS). An integrated barcode reader and printer are also available with most configurations.

Biosen can test blood, plasma or serum to provide glucose and lactate values with excellent precision (less than >2% CV) over a wide measurement range.

All Biosen analyzers in the range can be ordered as either one or two channel systems for measurements of either glucose or lactate, or both, in each of the following models:

  • Biosen C-Line GP+ : Up to 5 samples
  • Biosen C-Line Clinic : Up to 20 samples
  • Biosen S-Line Lab+ : Up to 63 samples

Specifications


Easy to use

  • Multi-lingual touch screen display with step by step instructions
  • Just 20 μl blood, plasma or serum sample required when used with EKF pre-filled 'Safe-Lock' reaction cups (1,000 μl)
  • Up to 120 results an hour
  • Results in 20-45 seconds
  • Automatically detects presence of reaction cups
  • Chip sensors easily exchangeable, no electrode cleaning required

Accurate and reliable

  • Enzymatic-amperometric method using chip-sensor technology
  • Measuring range: Glucose 0.5–50 mmol/L (9–900 mg/dL); Lactate 0.5–40 mmol/L (5–360 mg/dL)
  • Imprecision: CV ≤1.5 % (12 mmol/L)
  • Pre-filled ‘Safe-Lock’ reaction cups eliminate manual dilution
  • Innovative needle and exchanger design eliminates cross contamination
  • Three calibration modes

Frequently asked questions

Maximum efficiency and convenience

  • Dual channel option: Glucose and/or lactate results from one sample
  • Long sensor life: Glucose 60 days / 7,500 tests; Lactate 50 days / 6,000 tests
  • Sample stable for up to five days (refrigeration recommended)
  • STAT position 

 

Efficient data handling

  • PC, network and printer connectivity via RS232C interfaces
  • Stores up to 1,000 results
  • Integrated barcode reader (optional) 

 